Customization: | Available |
---|---|
Warranty: | No Maintenance |
Craft: | Pultrusion |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Mechanical performance | Value | Units | Test method | |||||
Tensile strength | LW | 300-760 | Mpa | ASTM D-638 | ||||
CW | 80-120 | |||||||
Tensile modulus | LW | 18-36 | Gpa | ASTM D-638 | ||||
CW | 7-13 | |||||||
Flexural strength | LW | 300-700 | Mpa | ASTM D-790 | ||||
CW | 80-120 | |||||||
Flexural modulus | LW | 20-32 | Gpa | ASTM D-790 | ||||
CW | 7-12 | |||||||
Compressive strength | LW | 280 | Mpa | ASTM D-695 | ||||
CW | 105 | |||||||
Compressive modulus | LW | 21 | Gpa | ASTM D-695 | ||||
CW | 7.9 | |||||||
Interlayer shear strength | 50-80 | Mpa | ASTM D-2344 | |||||
Shear strength | 60-100 | Mpa | ASTM D-732 | |||||
Impact strength | 280 | KJ/M2 | ASTM D-256 | |||||
Physical property | Value | Units | Test method | |||||
Barcol Hardness | 45-65 | --- | ASTM D-495 | |||||
Water absorption (25ºC,24h) | 0.2-0.5 | % | ASTM D-570 | |||||
Density | 1.75-2.10 | g/cm3 | ASTM D-792 | |||||
Coefficient of thermal expansion (LW) | 5.0 | 10-6/ºC | ASTM D-696 | |||||
Coefficient of thermal conductivity | 0.4 | W/(m.K) | ASTM C-177 | |||||
Elongation to break | 0.9-2.8 | % | ASTM D-638 | |||||
Electrical property | Value | Units | Test method | |||||
Arc resistance(LW) | 120 | seconds | ASTM D-495 | |||||
Dielectric constant (PF) | 5 | @60hz | ASTM D-150 | |||||
Dielectric strength (PF) | 8 | KV/mm | ASTM D-149 | |||||
Dielectric strength (LW) | 1.6 | KV/mm | ASTM D-149 | |||||
Surface resistance | 1015-1012 | Ω | ASTM D-257 | |||||
Volume resistance | 1015-1012 | Ω.cm | ASTM D-257 | |||||
Flammability property | Value | Units | Test method | |||||
Tunnel test | Max 25 | second | ASTM E-4 | |||||
Oxygen data | 25-28 | % |
ASTM 2863 |
|||||
28-32 | ||||||||
>32 | ||||||||
Flammability classification | Self extinguish | ASTM D635 |