Customization: | Available |
---|---|
Surface Treatment: | Smooth |
Color: | Different Colors Can Be Achieved. |
Still deciding? Get samples of US$ 1/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Mechanical properties | Test averages | Unit | Test standard | |
Tensile strength | LW | 230 | MPa | GB 1447/ ASTM D-638 |
CW | 75 | |||
Tensile modulus | LW | 24.2 | GPa | GB 1447/ ASTM D-638 |
CW | 11 | |||
Compressive strength | LW | 280 | MPa | GB 1448/ ASTM D-695 |
CW | 105 | |||
Compressive modulus | LW | 21 | GPa | GB 1448/ ASTM D-695 |
CW | 7.9 | |||
Flexural strength | LW | 330 | MPa | GB 1449/ ASTM D-790 |
CW | 79 | |||
Flexural modulus | LW | 20 | GPa | GB 1449/ ASTM D-790 |
CW | 7.8 | |||
Interlayer shear strength | LW | 25 | MPa | GB 3357/ ASTM D-2344 |
Impact toughness | ---- | 280 | KJ/m 2 | GB 2451/ ASTM D-256 |
Physical property | Test average | Unit | Test standard | |
Barcol Hardness | 50 | ---- | GB 3854/ ASTM D-495 | |
Water absorption(25 centigrade,24h) | 0.5 | % | GB 1462/ ASTM D-570 | |
Gravity | 1.8 | g/cm 3 | GB 1463/ ASTM D-792 | |
Coefficient of thermal expansion(LW) | 5.0 | 10 -6 /°C | GB 2572/ ASTM D-696 | |
Coefficient of thermal conductivity | 0.4 | W/(m@K) | GB 3139/ ASTM C-518 | |
Electrical property | Test average | Unit | Test standard | |
Arc resistance(LW) | 120 | seconds | GB 1411/ ASTM D-495 | |
Dielectric strength(LW) | 1.6 | KV/mm | GB 1408/ ASTM D-149 | |
Dielectric strength(PF) | 8 | KV/mm | GB 1408/ ASTM D-149 | |
Dielectric constant(PF) | 5 | @60hz | GB 1409/ ASTM D-150 | |
Surface resistivity | 10 15 -10 12 | Ω | GB 1410/ ASTM D257 | |
Volume resistivity | 10 15 -10 12 | Ω@cm | GB 1410/ ASTM D257 | |
Flammability property | Test average | Unit | Test standard | |
Tunnel test | 25max. | ---- | ASTM E84 | |
Oxygen data | ≥32 | % | GB 8924/ ANSI UL-94 | |
Using the resin of flame retardant type can meet the above requirements. |